Determining Planck’s constant - Recording the current-voltage characteristics, selection of wavelengths using interference filters on the optical bench

P6.1.4.4
Determining Planck’s constant - Recording the current-voltage characteristics, selection of wavelengths using interference filters on the optical bench
Determining Planck’s constant - Recording the current-voltage characteristics, selection of wavelengths using interference filters on the optical bench Current-voltage characteristics of the photocell (P6.1.4.4)
Determining Planck’s constant - Recording the current-voltage characteristics, selection of wavelengths using interference filters on the optical bench

This product is classified as a dangerous good and is not available for online purchase.

For ordering the dangerous good or other information please contact our customer service center.
This experiment/set up contains dangerous goods.
These are not available for online purchase.
You may order the experiment/set up without the dangerous goods.


For ordering the dangerous good or other information please contact our customer service center.
Email: webshopuk@ld-didactic.de
Telephone:+49 (0) 22 33 / 604 – 319
Go to contact form

˟

Request an offer

Thank you for your inquiry. We will get back to you as soon as possible.

˟
This product contains dangerous substances!

Description

In the experiment P6.1.4.4 one of the emission lines from a mercury gas discharge lamp is selected by interference filters and focused onto the photocathode. The countervoltage of the anode is varied and the resulting current is measured with high sensitivity. The variation of the characteristic curves under irradiation with different wavelengths leads to the determination of Planck's constant h.

Components of equipment sets

1 558 77 Photocell for determining Planck's constant LD
1 558 791  4  Holder for photocell LD
1 460 335  8  Optical bench with standardised profile, 0.5 m LD
2 460 374  8  Optics rider, 90/50 LD
3 460 375  8  Optics rider, 120/50 LD
1 558 792  4  Filter wheel with diaphragm LD
1 468 401  4  Interference filter, 578 nm LD
1 468 402  4  Interference filter, 546 nm LD
1 468 403  8  Interference filter, 436 nm LD
1 468 404  8  Interference filter, 405 nm LD
1 468 406  4  Interference filter, 365 nm LD
1 460 03  4  Lens in frame, f=100 mm LD
1 460 26  8  Iris diaphragm LD
1 451 15  4  High pressure mercury lamp LD
1 451 195  4  Power supply unit for high-pressure mercury lamp LD
1 532 00 I-measuring amplifier D LD
1 524 013  8  Sensor-CASSY 2 LD
1 524 220  4  CASSY Lab 2 LD
2 576 81  4  Plug-in board safety socket, 20/10 LD
3 576 86  4  Monocell holder STE 2/50 LD
3 685 48  8  Mono cell 1.5 V (IEC R20) LD
1 577 93  4  Potentiometer, 1 kΩ, 10-turn, STE 4/50 LD
1 579 13  8  Toggle switch STE 2/19 LD
1 501 48  4  Bridging plugs STE 2/19, set of 10 LD
2 500 621  4  Safety experiment cable, 50 cm, red LD
2 500 622  4  Safety experiment cable, 50 cm, blue LD
1 500 644  8  Safety experiment cable, 100 cm, black LD
1 additionally required:
PC with Windows XP/Vista/7/8/10 (x86 or x64)
Print page

Contact Us

Technical Service & Support:

Online Service Portal
Do you have any questions or suggestions regarding our devices, products, experiments, equipment sets or about our software? You need spare parts? FORM

Repair Service
You would like to register a repair? FORM

Europe
For European distributors, please visit: European distributors
Worldwide requests
Please contact us per email: sales@ld-didactic.de

 Click here for our contact form and postal address.

Contact Us